Aeroflex 2050T SERIES Especificaciones Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
For the very latest specifications visit www.aeroflex.com
Q9.4: Can the IFR 2968 test other base station components
besides the transceiver?
Q9.5: Can I store and recall different TETRA system set-ups on
the IFR 2968?
Q9.6: Why doesn't the store / recall facility work when I try to
store /recall TETRA settings?
Q9.7: Can I use a FLASH memory card instead of a battery
backed SRAM memory card?
Q9.8: Can I capture a 2968 screen image and use it in PC appli-
cations?
QUESTIONS AND ANSWERS SECTION
Section 1 Q&A: IFR 2968 versions and options
QQ11..11
: What is the current software version for the IFR 2968?
How do I determine whether an IFR 2968 is fitted with the latest
software?
AA11..11
: The current software version is "Phase 3.2" (version 11.20).
If you purchase a new 2968 it will have this version of software.
To determine which software version is installed in a 2968, press
the [HELP/SET-UP] hardkey then the [VERSION] softkey and check
the version numbers as follows:
The current
PPhhaassee 33..22 ssooffttwwaarree
is identified as follows:
A4 TETRA APP 11.20 16/04/02 (see note)
A6/2 MAINCODE 4M 11.20 16/04/02
TETRA application 11.20 16/04/02
The previous
PPhhaassee 33..11 ssooffttwwaarree
is identified as follows:
A4 TETRA APP 11.10 18/01/01 (see note)
A6/2 MAINCODE 4M 11.10 18/01/01
TETRA application 11.10 18/01/01
The earlier
PPhhaassee 33..00 ssooffttwwaarree
is identified as follows:
A4 TETRA APP 11.00 25/04/00 (see note)
A6/2 MAINCODE 4M 11.00 25/04/00 or version 11.01
TETRA application 11.00 25/04/00
Note: Shown only when TETRA system is selected.
QQ11..22::
My IFR 2968 does not have the latest software version.
Can it be upgraded, and is there a charge for this?
AA11..22::
Yes, it can be upgraded to Phase 3.2. If your IFR 2968 has
the previous Phase 3.1 software (version 11.10) or the earlier
Phase 3.0 software (version 11.00 or 11.01) then there is no
charge for the upgrade to Phase 3.2. If your IFR 2968 has the ear-
lier Phase 3.0 software you can upgrade straight to Phase 3.2
without first upgrading to Phase 3.1. If your IFR 2968 has the even
earlier Phase 2 software (version 10.20 or lower) then you will
need to purchase the "2968 PHASE 3" option before your IFR
2968 can be upgraded. Please contact your local IFR sales rep-
resentative or distributor to arrange for an upgrade or to purchase
the option "2968 PHASE 3".
QQ11..33::
Do I have to return the IFR 2968 to IFR for the software
upgrade?
AA11..33::
No, this is not normally necessary. The software upgrade
will normally be performed by your local IFR Approved Service
Center, either on your premises or by return to a local service cen-
ter, as agreed between you and the IFR Approved Service Center.
The process takes about 45 minutes and does not require disas-
sembly of the test set. However, if the IFR 2968 is due to be
returned to an IFR Approved Service Center for repair or routine
calibration, then the software upgrade can be requested at the
same time. If your test set is a very early unit that has never been
upgraded then it may require return to your local IFR Approved
Service Center.
QQ11..44::
Is there a new version of the 2968 operating manual for
the Phase 3.2 upgrade?
A1.4: Yes, but only the TETRA specific aspects have
changed. Current versions are:
46882/274 Operating Manual for
2965/2966/2967/2968: issue 13, 25 June 2001
46882/324 TETRA Supplement for 2968 Phase 3.2:
issue 10, 17 May 2002
46882/280 Programming Manual for
2965/2966/2967/2968: issue 12, 21 March 2002
If you receive a free-of-charge upgrade to Phase 3.2 from Phase
3.1 or Phase 3.0 you can also receive free-of-charge electronic
copies of the updated TETRA supplement and programming man-
ual in pdf format. If you are purchasing the "2968 PHASE 3"
option to upgrade to Phase 3.2 from Phase 2, you will receive a
new printed copy of the TETRA supplement. You may also pur-
chase printed copies of any of the manuals if required - please
contact your usual IFR sales representative. If you purchase a new
2968 you will receive printed copies of all 3 manuals.
QQ11..55::
What are the new functions in the Phase 3.2 software?
AA11..55::
The following is a brief summary of the new functions in the
IFR 2968 Phase 3.2 software release with respect to the previous
Phase 3.1 release.
TETRA Test (TT) mode registration obtains TEI, Power
Class, Receiver Class
TETRA Test (TT) RF Loopback and TCH/S BER /
RBER / MER measurement
Enhanced autotest with up to six configurable call set-up
and clear-down tests
TIPv3 Compliant
Mobile Originated SDS-TL text message, 160 characters
with destination SSI / ESN
Mobile Terminated SDS-TL text message, 120 characters
user definable, timestamp
Mobile Originated and Mobile Terminated 7-bit SDS-TL
text messages
SDS-TL Short Reports sent and received
Mobile Originated Status with destination SSI / ESN
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 23 24

Comentarios a estos manuales

Sin comentarios